Sign In | Join Free | My adobecards.com |
|
Brand Name : BAXIT
Model Number : BXT-MPCVD
Certification : CE
MOQ : 1(Min. Order)
Price : USD149080- 150000Set|1 Set/Sets(Min. Order)
Payment Terms : L/C, T/T, D/A, D/P
Supply Ability : 5
Delivery Time : 5-8work days
Place of Origin : China
Operating frequency : 2450MHz
Output power : 0.1 ~ 6 kW continuously adjustable
Power stability : better than ±1% (@ rated status)
Output waveguide interface : BJ-26/22 with FD-26/22 standard flange
Power input : 380VAC/50Hz, 3-phase 5-wire, 11kW
Cooling water flow : 18L/min
System standing wave coefficient : VSWR ≤ 1.5
Microwave leakage : meet the national standards
Size and working mode : Φ200 x 300 (H) TM mode
Microwave generator and system | Operating frequency | 2450MHz |
Output power | 0.1 ~ 6 kW continuously adjustable | |
Power stability | better than ±1% (@ rated status) | |
Output waveguide interface | BJ-26/22 with FD-26/22 standard flange | |
Power input | 380VAC/50Hz, 3-phase 5-wire, 11kW | |
Cooling water flow | 18L/min | |
System standing wave coefficient | VSWR ≤ 1.5 | |
Microwave leakage | meet the national standards | |
Microwave vacuum discharge chamber | Size and working mode | Φ200 x 300 (H) TM mode |
Effective deposition area | Φ50mm | |
Pressure control range | 0.5KPa~30KPa | |
Pressure control accuracy | ±15Pa | |
Vacuum acquisition | Single crystal growth | growth rate of 10-15μm/H, single growth thickness ≥ 1.6mm |
Single crystal quality | almost no defects under naked eye | |
Vacuum system | Blowout mode | fill with N2 |
Ultimate vacuum degree | better than8×10-4Pa | |
Vacuum leakage rate | ≤10-9pA.m3/s | |
Pressure rise | 24 hours average pressure rise is less than1Pa/H |
Gas mass flow system | Accuracy | 2%-100%F.S.,inletpressureis0.2-0.3Mpa |
Gas type and range | H2(1SLM),CH4(100SCCM),O2(10SCCM),N2(20SCCM) | |
Sample stage system | Sample stage diameter | Φ60mm,water-cooled; |
Adjustment range of sample table | 0~15mm | |
Cavity plate adjustment range | 0~60mm | |
Substrate temperature measurement | infrared temperature measurement range | 600~1200℃(Infrared temperature measurement) |
Temperature control precision | temperature control precision±5℃; | |
Control range of constant temperature area | temperature difference of each point of molybdenum platform≤30℃ | |
Device interface | Inlet and outlet water | G1"outer wire |
Gas connection | 1/4"VCR outer wire | |
Exhaust discharge interface | 3/4"outer wire | |
Power line | TB4506 | |
Insulation resistance | ≥5MΩ | |
Reliability | the continuous and stable working time under normal conditions shall not be less than 24H | |
Total power supply | 380VAC±5%/50Hz,3phase5wire,13kW | |
Total cooling water | 34L/min,clean soft water,inlet water temperature is 20℃±5℃;Water pressure is 0.2~0.4MPa | |
Dimensions | ~1.95(L)x0.8(W)x1.90(H)m |
![]() |
lab-grown diamond machine MPCVD equipment Diamond professional growth equipment CVD diamond growing machine manufacturer Images |